IRB60, 80, 120 metal clad, wire wound resistors are ideal for applications that require 60W,80W,120W or less and
are on a budget. These models come in a durable metal case have flying leads.GENERAL SPECIFICATIONS
MODEL
Power rating [W]
Resistance Range [§Ù]
Inductive
Non-Inductive
IRB 60
60
0.1-270
0.1-56
IRB 80
80
0.1-910
0.1-110
IRB120
120
0.1-1.3K
0.1-300
Available Tolerances: G (+-2%), H (+-3%), J (+-5%), K (+-10%), M (+-20%)
DIMENSIONS
MODEL
DIMENSIONS
L1
L2
D
W
L3
H
IRB60
100+-1.5
90+-1.5
5+-0.2
32.3+-0.5
75+-1
12.3+-1
IRB80
150+-2
140+-2
4.2+-0.5
34+-1
130+-2
20+-1
IRB120
182+-1
170+-1
5+-0.2
44+-1
150+-1
13+-0.5
CHARACTERISTICS Values in [ ] mean change in ohmic value after test
Temperature Range
-55C to 200C
Insulation Resistance
20Mohm min.
Dielectric Strength
Available options: AC 1500V,3500V,4500V,5400V MAX. leakage current: 2mA
Temp. Coefficient
+- 260ppm/C maximum
Short time overload
(2%+0.05§Ù) 60W:5¡¿wattage rating, 80W, 120W:10¡¿wattage rating-5 sec.
Moisture Resistance
(3%+0.05§Ù) 40C, 95% RH, DC100V case to terminal (500hrs.)
Thermal Shock
(2%+0.05§Ù) wattage rating 30 min., -25C, 15 min.
Vibration
(1%+0.05§Ù) 10Hz-55Hz-10Hz (1 min.), 2hrs.each direction
Moisture Load Life
(3%+0.05§Ù) 40C, 95%RH, 0.1¡¿wattage rating, 1.5hrs.on, 30min. off, 1000hrs.
Load Life
(5%+0.05§Ù) wattage rating 1.5h. on, 30min.off, 1000hrs.
SURFACE TEMPERATURE INCREASE CURVE
DERATING CURVE
ORDERING PROCEDURE EXAMPLE
Copyright©, RARA Electronics Corporation