HOME INTRO HISTORY PRODUCTS NEWS
|
SPT |
Download PDF File |
![]() |
SPT sub-miniature fuses are extremely small and an excellent choice to accommodate
PCB space requirements. Available in 1 to 6.3 amps. Built according to IEC 60127-3/4.
Has several approvals including: VDE, CCC, cUL, SEMKO, PSE and EK. Interrupting rating
of 35A or 10X rated current, whichever is greater.GENERAL SPECIFICATIONS
Model
Ampere Rating(A)
Voltage Rating(V)
Nominal Resistance
Cold Ohms(¥Ø)Nominal Melting I2t(A2s)
SPT 1A00
1
250
0.073
9.7
SPT 1A25
1.25
0.051
12.3
SPT 1A60
1.6
0.041
17.8
SPT 2A00
2
0.031
33.0
SPT 2A50
2.5
0.023
47.0
SPT 3A15
3.15
0.017
62.5
SPT 4A00
4
0.013
102.0
SPT 5A00
5
0.010
163.0
SPT 6A30
6.3
0.007
235.0
CHARACTERISTICS Values in [ ] mean change in §Ù after test
Voltage drop
Max. Voltage drop(mV)
All electrical test is to conducted with the ambient air at a temperature of 25¡¾3¡É. The air temperature is not to vary
more than 5C during the test, and to be within these limits.1A
140
1.25A
130
1.6A
120
2A
100
2.4A
100
3.15A
100
4A
100
5A
100
6.3A
90
Endurance
The voltage drop increase shall be less than 10% of the Value before the test.
S100 cycles of rated current (DC) carry for 1hr, then switch off for 15min. Followed by 1hr at 1.5 ln. f.
Test at an elevated
Temperature 70CNot operate
A current of 1.0 ln shall be passed through the fuse-links or 1hr
Insulation
0.1M¥Ø min. measured by
500V dc insulation testerAfter overload test or Breaking Capacity test
DIMENSIONS
Model
Dimension(mm)
L¡¾1.0
H¡¾0.2
L¡¾3.0
P¡¾0.05
Min h
D¡¾0.2
¥Õd¡¾0.03
SPT TE
8.4
7.9
4.3
5.05
0.5
4.3
0.02
SPT TS
6.5
AVERAGE TIME CURRENT CURVE AND AMPERE RATING
% of Ampere Rating
Opening Time
210%
2minutes, Maximum
275%
0.4sec min : 10seconds Maximum
400%
0.15sec min : 3seconds Maximum
1000%
0.02sec min : 0.15seconds Maximum
ORDERING PROCEDURE EXAMPLE
Copyright©, RARA Electronics Corporation