HOME   INTRO   HISTORY   PRODUCTS   NEWS

DBU
DYNAMIC BRAKING UNIT

 

- Used for load with relatively high damping frequency (ED), 20%.
- Up to a max of 4 parallel driving control units is possible.
- Used for load with high damping frequency.

GENERAL SPECIFICATIONS

Model

Max Input Direct Current Voltage

Applicable Inverter Capacity [kW]

Damping Resistance

Capacity[kW]

Min Resistance Value[§Ù]

IT150DBU-2H

200V series
DC 400V

11 kW

15 kW

3.2 kW

8.5 §Ù

IT220DBU-2H

18.5 kW

22 kW

30 kW

4.8 kW

5.7 §Ù

IT370DBU-2H

37 kW

45 kW

6.4 kW

4.2 §Ù

IT550DBU-2H

55 kW

9.6 kW

2.8 §Ù

IT150DBU-4H

400V series
DC 800V

11 kW

15 kW

3.2 kW

33.9 §Ù

IT220DBU-4H

18.5 kW

22 kW

4.8 kW

22.8 §Ù

IT370DBU-4H

30 kW

37 kW

6.4 kW

16.9 §Ù

IT550DBU-4H

45 kW

55 kW

9.6 kW

11.4 §Ù

IT750DBU-4H

75 kW

12.8 kW

8.4 §Ù

CHARACTERISTICS

Surrounding Temp

-10C ~ 40C

Humidity

Relative humidity of under 90% RH (Should be no dew condensation)

Altitude

Under 1000m above the sea level

Cooling way

Natural cooling

Surrounding circumstance

There should be no corrosive gas inside panel, oil , inflammable gas and dust inside panel.

Max Turn  on time

6sec

Protecting function

Protection of heat sink¡¯s overheating, over current and output shortcut

Output signal

HEAT SINK heating, FUSE OPEN, OC trip signal

Parallel driving

Up to a max of 3 parallel driving units is possible.

Allowed damping freq.

Without cooling FAN, 10%

Ave damping torque

100%